Enter the Start Frequency and the End (Stop) Frequency using the Special Function
Keys located on the lower side of the LCD display and the numeric keys followed by
the [ENT] key ([KHz] key or [MHz] key.)
[Memo: Displayed frequency range:
Spectrum Analyzer Mode --- CF (Center Frequency) +/- (Frequency span/2)
Step Resolution Mode --- CF (Center Frequency) +/- (Display step x 160)
The Frequency span on the above example: 25 KHz x 320 steps = 8 MHz)
6-6-3 Channel Scope Mode
On the above screen, the following information is displayed.
Start frequency: 118.0 MHz
Step frequency: 25 KHz
End (Stop) frequency: 122.0 MHz
Frequency span: 4 MHz
Marker frequency: 121.8 MHz
Receive marker frequency:119.7 MHz
Unlike the Spectrum Analyzer mode or Step Resolution mode, the CF (Center
Frequency) setting is not available in the Channel Scope Mode.
Start Frequency (Ch. START
)
Press the [Ch. START] key using the left Special Function Keys. The icon indicating
the current start frequency will be reversed prompting the entry of new start frequency.